Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
J. health sci. (Londrina) ; 21(3): https://seer.pgsskroton.com/index.php/JHealthSci/article/view/6602, 24/09/2019.
Article in English | LILACS-Express | LILACS | ID: biblio-1051492

ABSTRACT

Individuals with chronic renal failure (CRD) undergo hemodialysis to compensate for systemic-based disease and often develop systemic arterial hypertension (SAH). Such individuals, when needing dental treatment, carry with them the consideration of which type of anesthetic to be used in clinical and surgical interventions. The objective of this study was to evaluate the action of anesthetics with vasoconstrictor (AwV) and without vasoconstrictor (AoV) in individuals with chronic renal failure. Research subjects needed dental treatment, with dental restorations, on the right and left lower dental arch in premolars and / or molars, thus receiving the model of a split-mouth clinical study. In a randomized study, each side of the mandible was subjected to an anesthetic infiltration with only one 1.8 mL tube in two different moments with a minimum interval of 7 days (for one moment with AwV and another AoV moment). The parameters of oxygen saturation (SaO2), heart rate (HR), systolic blood pressure (SBP) and diastolic blood pressure (DBP) were measured 5 minutes before anesthesia, 5, 15 and 30 minutes after anesthesia. The results found in this study showed statistical difference only in SaO2 in the time of 5 minutes after the anesthesia in comparison of the AwV and AoV group, this same result was obtained when only those individuals who, besides nephropathies, had a diagnosis of SAH, were evaluated. The findings of this study highlight the safety of the use of anesthetics, with or without vasoconstrictors since in small amounts, in individuals with CRF with or without associated SAH. (AU)


Indivíduos com insuficiência renal crônica (IRC) em geral são submetidos à hemodiálise para compensação da doença de base sistêmica e frequentemente desenvolvem a hipertensão arterial sistêmica (HAS). Tais indivíduos, ao necessitarem de tratamento odontológico, levam consigo a ponderação de qual tipo de anestésico a ser utilizado em intervenções clínicas e cirúrgicas. O objetivo deste estudo foi avaliar a ação de anestésicos com vasoconstritor (ACV) e sem vasoconstritor (ASV) em indivíduos com insuficiência renal crônica. Os indivíduos da pesquisa tinham necessidade de tratamento odontológico, com restaurações dentárias, no arco dentário inferior direito e esquerdo em pré-molares e/ou molares, recebendo assim o modelo de estudo clínico de boca dividida. De forma aleatória, os hemiarcos inferiores foram submetidos, em dois diferentes momentos com intervalo mínimo de 7 dias, a infiltração anestésica com apenas um tubete de 1,8 mL (para um momento com ACV e outro momento ASV). Foi feita aferição dos parâmetros de saturação de oxigênio (SaO2), frequência cardíaca (FC), pressão arterial sistólica (PAS) e diastólicas (PAD), 5 minutos antes da anestesia, 5, 15 e 30 minutos após a anestesia. Os resultados encontrados neste estudo demonstraram diferença estatística apenas na SaO2 no tempo de 5 minutos após a anestesia em comparação do grupo ACV e ASV, esse mesmo resultado foi obtido quando avaliados apenas os indivíduos que, além de nefropatas, apresentavam diagnóstico de HAS. Os achados deste estudo ressaltam a segurança do uso de anestésicos, com ou sem vasoconstritores desde que em pequenas quantidades, em indivíduos com IRC com ou sem HAS associada. (AU)

2.
Periodontia ; 21(4): 76-79, 2011. tab
Article in Portuguese | LILACS, BBO | ID: lil-642423

ABSTRACT

Objetivo: o presente estudo tem por objetivo avaliar a função hepática frente à ingestão de álcool associado com a periodontite induzida por ligadura em ratas Lewis. Materiais e Métodos: os 24 animais foram divididos nos grupos: álcool+ligadura-GA (n=8), ligadura-GL (n=8) e controle negativo -GCN (n=8). Para a análise dos resultados foram adotados os parâmetros bioquímicos – aspartato aminotransferase (ASTTGO) e transaminase glutâmica pirúvica (ALTTGP). Os animais foram submetidos à ingestão de solução alcoólica a 20%, ao longo de um período de 60 dias. Para o procedimento de indução da doença periodontal, os animais do GA e GL receberam anestesia geral. Resultados: os resultados do trabalho demonstraram ausência de diferença estatística (p>0,05) para as variáveis ASTTGO e ALTTGP paras os grupos GA, GL e GCN. Conclusão: conclui-se que a ingestão de álcool na dosagem praticada, associado à periodontite induzida por ligadura não modificou os exames de bioquímica ASTTGO e ALTTGP em ratas Lewis.


Objective: This study aims to assess liver function before the intake of alcohol associated with ligature-induced periodontitis in rats Lewis. Materials and Methods: These 24 animals were divided into two groups: alcohol + GA-ligation (n = 8), ligation-GL (n = 8) and negative control-GCN (n = 8). For the analysis of the results were used biochemical parameters – aspartate aminotransferase (AST AST) and glutamic pyruvic transaminase (ALT TGP). The animals were submitted to the ingestion of alcoholic solution at 20% over a period of 60 days. For the induction of periodontal disease, animals in the GL and GA general anesthesia. Results: The results demonstrated no statistical difference (p> 0.05) for the variables AST AST and ALT TGP paras the GA, GL and GCN. Conclusion: We conclude that alcohol intake at a dose practiced, associated with ligature-induced periodontitis did not modify the biochemical tests AST AST and ALT TGP Lewis in rats.


Subject(s)
Animals , Rats , Alcoholism , Rats, Inbred Lew
3.
Rev. odonto ciênc ; 25(2): 178-181, 2010. tab
Article in English | LILACS, BBO | ID: lil-573165

ABSTRACT

Purpose: The aim of this in vitro study was to evaluate the effect of mouthwashes with and without alcohol on some microorganisms. Methods: Periogard®, Cepacol®, Plax Classic® and Oral-B® were the substances tested. For this study, 40 plates of Petri with medium blood agar were used for the following microorganisms: Staphylococcus aureus, Candida albicans, Enterococcus faecalis, Pseudomonas aeruginosa. To measure the inhibition zones, a single trained examiner used a stereomicroscope and a digital caliper. After data collection, the medias were compared using the ANOVA (analysis of variance) with Bonferroni test post-hoc correction for 5% significance level. Results: Periogard®, with and without alcohol, showed the best results. Plax® without alcohol presented the poorest results. Plax® with alcohol was the best substance in relation to S. aureus. The others results remained with better effectiveness in relation to control substance. Conclusion: The alcohol-free mouthwashes did not have the same efficacy of antimicrobial rinses with alcohol in relation to microorganisms tested in this study.


Objetivo: O objetivo desse estudo in vitro foi de avaliar a ação antimicrobiana de enxaguatórios bucais com e sem álcool. Metodologia: Usaram-se no estudo o Periogard®, o CEPACOL®, Plax Classic® e o ORAL-B®, anti-séptico sem álcool. Para a realização desse estudo foram utilizadas 40 placas de Petri com meio de cultura de Ágar Sangue para os seguintes microrganismos: Staphylococcus aureus, Candida albicans, Enterococcus faecalis, Pseudomonas aeruginosa. Para a mensuração dos halos de inibição, um único examinador treinado utilizou uma lupa estereoscópica e um paquímetro digital. Após a coleta dos dados, as médias foram comparadas utilizando-se do teste estatístico ANOVA (análise de variância) com teste corretivo de Bonferroni, para nível de significância de 5%. Resultados: O Periogard® com álcool e o sem álcool apresentaram os melhores resultados. O Plax® sem álcool obteve os piores resultados. O Plax® com álcool foi melhor substância em relação ao S. aureus. Os demais resultados mantiveram-se com melhor efetividade em relação à substância controle. Conclusão: Os enxaguatórios sem álcool não têm a mesma eficácia antimicrobiana comparada aos enxaguatórios com álcool em relação aos microrganismos testados neste estudo.


Subject(s)
Mouthwashes , Candida albicans , Enterococcus faecalis , In Vitro Techniques , Pseudomonas aeruginosa , Staphylococcus aureus
4.
Periodontia ; 17(3): 62-66, set. 2007. tab
Article in Portuguese | LILACS, BBO | ID: lil-524095

ABSTRACT

O objetivo deste trabalho foi pesquisar o efeito do estresse crônico na progressão da periodontite induzida por ligadura em ratos. Para o estudo foram utilizados 24 ratos adultos da espécie Rattus novergicus da linhagem Wistar, distribuídos em grupo estresse, ligadura e controle. Após anestesia dos grupos estresse e ligadura, colocou-se fio de seda em volta do segundo molar superior direito de cada animal. No grupo estresse, um dia após a indução de periodontite, os animais foram submetidos a ensaio de estresse crônico, alternando-se o modelo de contenção em um dia e contenção associado à exposição ao frio no outro, ambos uma vez ao dia, durante duas horas. Nos grupos ligadura e controle nenhum estresse foi realizado. Decorrido o período de 60 dias de estresse, todos os grupos foram eutanasiados por dose excessiva de anestésico. Na avaliação histométrica, foram determinadas as distâncias entre ajunção amelo-cementária na face mesial do segundo molar até a porção mais coronária do epitélio juncional (Jac-I) e crista óssea alveolar (Jac-CO). Foram observadas diferenças significativas(p<0,05) entre os grupos estresse, ligadura e controle para as médias Jac-I (1,32 mm, 0,58 mm e 0 mm respectivamente) e Jac-CO (2,64 mm, 1,74 mm e 0,95 mm, respectivamente). Concluindo, o modelo de estresse crônico foi capaz de induzir a maior progressão de periodontite induzida porligadura em ratos.


Subject(s)
Rats , Stress, Physiological , Periodontitis
5.
Periodontia ; 16(3): 5-11, set. 2006. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-463287

ABSTRACT

Em instituições que não dispõem de câmara acoplada ao microscópio, buscam-se alternativas para análises histométricas. Com esse objetivo, compararam-se os resultados de dois métodos histométricos distintos em periodontite de ratos. Após anestesia, posicionou-se um fio de seda em volta do segundo molar superior direito, e aguardaram-se 60 dias para a eutanásia. As peças foram preparadas, coradas e montadas.A análise histométrica utilizada foi a distância entre a junção amelocementária na face mesial do segundo molar até a fibra periodontal inserida (Jac-F) e a crista óssea alveolar (Jac-O). Empregaram-se dois métodos de histometria, imagem digitalizada e retroprojetor de lâminas. A partir da obtenção dos dados, foram realizadas as médias dos grupos e comparadas. Os dados foram submetidos à análise estatística, utilizando o teste T para amostras independentes (p<0,05). Os resultados das médias para Jac-F foram 0,97 mm para imagem digitalizada e l, 13 mm para imagem do retroprojetor; já para Jac-O, foram 3,1 mm para imagem digitalizada e 2,8 mm para imagem do retroprojetor.Não se observaram diferenças significativas (p>0,05) entre os grupos, tanto para Jac-F como Jac-O. Conclui-se que as duas metodologias de avaliação histométrica podem fornecer similaridades nos resultados.


Subject(s)
Animals , Rats , Alveolar Bone Loss , Diagnostic Imaging/methods , Image Interpretation, Computer-Assisted , Periodontitis/chemically induced , Image Processing, Computer-Assisted/methods , Histological Techniques
SELECTION OF CITATIONS
SEARCH DETAIL